Indoor air quality (IAQ) is the air quality within and around buildings and structures. Poor indoor air quality due to indoor air pollution is known to affect the health, comfort, and well-being of building occupants. It has also been linked to sick building syndrome, reduced productivity, and impaired learning in schools. Common pollutants of indoor air include: secondhand tobacco smoke, air pollutants from indoor combustion, radon, molds and other allergens, carbon monoxide, volatile organic compounds, legionella and other bacteria, asbestos fibers, carbon dioxide,[1] ozone and particulates. Source control, filtration, and the use of ventilation to dilute contaminants are the primary methods for improving indoor air quality.

IAQ is evaluated through collection of air samples, monitoring human exposure to pollutants, analysis of building surfaces, and computer modelling of air flow inside buildings. IAQ is part of indoor environmental quality (IEQ), along with other factors that exert an influence on physical and psychological aspects of life indoors (e.g., lighting, visual quality, acoustics, and thermal comfort).[2]

Employees working in indoor workplaces such as offices, retail stores, hospitals, libraries, schools and preschool childcare facilities can also be effected by poor IAQ. They may exhibit symptoms associated with sick building syndrome including burning of the eyes, scratchy throat, blocked nose, and headaches.[3]

Indoor air pollution is a major health hazard in developing countries and is commonly referred to as "household air pollution" in that context.[4] It is mostly relating to cooking and heating methods by burning biomass fuel, in the form of wood, charcoal, dung, and crop residue, in indoor environments that lack proper ventilation. Millions of people, primarily women and children face serious health risks. In total, about three billion people in developing countries are affected by this problem. The World Health Organization (WHO) estimates that cooking-related indoor air pollution causes 3.8 million annual deaths.[5] The Global Burden of Disease study estimated the number of deaths in 2017 at 1.6 million.[6]

Definition

The average adult breathes approximately 11,000 liters of air per day.[7] For health reasons it is crucial to breathe clean air, free from chemicals and toxicants to the extent possible. It is estimated that humans spend approximately 90% of their lifetime indoors [8] and that indoor air pollution can be much worse than that of the ambient air.[9][10] There are different factors that contribute to the high concentration of pollutants indoors, ranging from off-gassing by furniture, furnishings including carpets, indoor activities (cooking, cleaning, painting, smoking, etc. in homes to using office equipment in offices), thermal comfort parameters such as temperature, humidity, airflow and physio-chemical properties of the indoor air.Шаблон:Citation needed There have been many debates among indoor air quality specialists about the proper definition of indoor air quality and specifically what constitutes "acceptable" indoor air quality.

Common pollutants

Secondhand tobacco smoke

Шаблон:Main Secondhand smoke is tobacco smoke which affects people other than the 'active' smoker. It is made up of the exhaled smoke (15%) and mostly of smoke coming from the burning end of the cigarette, known as sidestream smoke (85%).[11]

Secondhand smoke contains more than 7000 chemicals, of which hundreds are harmful to health.[11] Secondhand tobacco smoke includes both a gaseous and a particulate materials which, with particular hazards arising from levels of carbon monoxide and very small particulates (fine particulate matter, especially PM2.5 and PM10) which get into the bronchioles and alveoles in the lung.[12] Inhaling secondhand smoke on multiple occasions can cause asthma, pneumonia, lung cancer, and sudden infant death syndrome, among other conditions.[13]

The only certain method to improve indoor air quality as regards secondhand smoke is to eliminate smoking indoors.[14] Indoor e-cigarette use also increases home particulate matter concentrations.[15]

Air pollutants from indoor combustion

Шаблон:Main Шаблон:Further

a 3-stone stove
A traditional wood-fired 3-stone stove in Guatemala, which causes indoor air pollution

Indoor combustion, such as for cooking or heating, is a major cause of indoor air pollution and causes significant health harms and premature deaths. Hydrocarbon fires cause air pollution. Pollution is caused by both biomass and fossil fuels of various types, but some forms of fuels are more harmful than others. Indoor fire can produce black carbon particles, nitrogen oxides, sulfur oxides, and mercury compounds, among other emissions.[16] Around 3 billion people cook over open fires or on rudimentary cook stoves. Cooking fuels are coal, wood, animal dung, and crop residues.[17]

Radon

Шаблон:Main Radon is an invisible, radioactive atomic gas that results from the radioactive decay of radium, which may be found in rock formations beneath buildings or in certain building materials themselves.

Radon is probably the most pervasive serious hazard for indoor air in the United States and Europe. It is a major cause of lung cancer, responsible for 3–14% of cases in countries, leading to tens of thousands of deaths.[18]

Radon gas enters buildings as a soil gas and is a heavy gas and thus will tend to accumulate at the lowest level. Radon may also be introduced into a building through drinking water particularly from bathroom showers. Building materials can be a rare source of radon, but little testing is carried out for stone, rock or tile products brought into building sites; radon accumulation is greatest for well insulated homes.[19] There are relatively simple test kits for do-it-yourself radon gas testing, but a licensed professional can also check homes.

The half-life for radon is 3.8 days, indicating that once the source is removed, the hazard will be greatly reduced within a few weeks. Radon mitigation methods include sealing concrete slab floors, basement foundations, water drainage systems, or by increasing ventilation.[20] They are usually cost effective and can greatly reduce or even eliminate the contamination and the associated health risks.Шаблон:Cn

Radon is measured in picocuries per liter of air (pCi/L) or becquerel per cubic meter (Bq m-3). Both are measurements of radioactivity. The World Health Organization (WHO) sets the ideal indoor radon levels at 100 Bq/m-3.[21] In the United States, it is recommend to fix homes with radon levels at or above 4 pCi/L. At the same time it is also recommends that people think about fixing their homes for radon levels between 2 pCi/L and 4 pCi/L.[22] In the United Kingdom the ideal is presence of radon indoors is 100 Bq/m-3. Action needs to be taken in homes with 200 Bq/m-3 or more.[23]

Molds and other allergens

Шаблон:Main

Occupants in buildings can be exposed to fungal spores, cell fragments, or mycotoxins which can arise from a host of means, but there are two common classes: (a) excess moisture induced growth of mold colonies and (b) natural substances released into the air such as animal dander and plant pollen.[24]

Mold is always associated with moisture,[25] and its growth can be inhibited by keeping humidity levels below 50%. Moisture buildup inside buildings may arise from water penetrating compromised areas of the building envelope or skin, from plumbing leaks, from condensation due to improper ventilation, or from ground moisture penetrating a building part. Even something as simple as drying clothes indoors on radiators can increase the risk of exposure to (amongst other things) Aspergillus – a highly dangerous mould that can be fatal for asthma sufferers and the elderly. In areas where cellulosic materials (paper and wood, including drywall) become moist and fail to dry within 48 hours, mold mildew can propagate and release allergenic spores into the air.

In many cases, if materials have failed to dry out several days after the suspected water event, mold growth is suspected within wall cavities even if it is not immediately visible. Through a mold investigation, which may include destructive inspection, one should be able to determine the presence or absence of mold. In a situation where there is visible mold and the indoor air quality may have been compromised, mold remediation may be needed.

There are some varieties of mold that contain toxic compounds (mycotoxins). However, exposure to hazardous levels of mycotoxin via inhalation is not possible in most cases, as toxins are produced by the fungal body and are not at significant levels in the released spores. The primary hazard of mold growth, as it relates to indoor air quality, comes from the allergenic properties of the spore cell wall. More serious than most allergenic properties is the ability of mold to trigger episodes in persons that already have asthma, a serious respiratory disease.

Infants in homes with mold have a much greater risk of developing asthma and allergic rhinitis.[24] More than half of adult workers in moldy or humid buildings suffer from nasal or sinus symptoms due to mold exposure.[24]

Carbon monoxide

Шаблон:Main One of the most acutely toxic indoor air contaminants is carbon monoxide (CO), a colourless and odourless gas that is a by-product of incomplete combustion. Common sources of carbon monoxide are tobacco smoke, space heaters using fossil fuels, defective central heating furnaces and automobile exhaust. By depriving the brain of oxygen, high levels of carbon monoxide can lead to nausea, unconsciousness and death.

The recommended levels of indoor CO exposure in 24 hours is 7 mg/m3. Acute exposure should not exceed 10 mg/m3 in 8 hours, 35 mg/m3 in one hour and 100 mg/m3 in 15 minutes.[26]

Volatile organic compounds

Volatile organic compounds (VOCs) include a variety of chemicals, some of which may have short- and long-term adverse health effects. VOCs presenting health hazards include benzene, formaldehyde, tetrachloroethylene and trichloroethylene.[27]

Concentrations of many VOCs are consistently higher indoors (up to ten times higher) than outdoors. VOCs are emitted by thousands of products. Examples include: paints and lacquers, paint strippers, cleaning supplies, pesticides, building materials and furnishings, office equipment such as copiers and printers, correction fluids and carbonless copy paper, graphics and craft materials including glues and adhesives, permanent markers, and photographic solutions.[28] Chlorinated drinking water releases chloroform when hot water is used in the home. Benzene is emitted from fuel stored in attached garages. Overheated cooking oils emit acrolein and formaldehyde.

Organic chemicals are widely used as ingredients in household products. Paints, varnishes, and wax all contain organic solvents, as do many cleaning, disinfecting, cosmetic, degreasing, and hobby products. Fuels are made up of organic chemicals. Testing emissions from building materials used indoors has become increasingly common for floor coverings, paints, and many other important indoor building materials and finishes.[29]

Indoor materials such as gypsum boards or carpet act as VOC 'sinks', by trapping VOC vapors for extended periods of time, and releasing them by outgassing. This can result in chronic and low-level exposures to VOCs.[30]

Several initiatives aim to reduce indoor air contamination by limiting VOC emissions from products. There are regulations in France and in Germany, and numerous voluntary ecolabels and rating systems containing low VOC emissions criteria such as EMICODE,[31] M1,[32] Blue Angel[33] and Indoor Air Comfort[34] in Europe, as well as California Standard CDPH Section 01350[35] and several others in the US. Due to these initiatives an increasing number of low-emitting products became available to purchase.

At least 18 microbial VOCs (MVOCs) have been characterised[36][37] including 1-octen-3-ol (mushroom alcohol), 3-Methylfuran, 2-pentanol, 2-hexanone, 2-heptanone, 3-octanone, 3-octanol, 2-octen-1-ol, 1-octene, 2-pentanone, 2-nonanone, borneol, geosmin, 1-butanol, 3-methyl-1-butanol, 3-methyl-2-butanol, and thujopsene. The last four are products of Stachybotrys chartarum, which has been linked with sick building syndrome.[36]

Legionella

Legionnaires' disease is caused by a waterborne bacterium Legionella that grows best in slow-moving or still, warm water. The primary route of exposure is through the creation of an aerosol effect, most commonly from evaporative cooling towers or showerheads. A common source of Legionella in commercial buildings is from poorly placed or maintained evaporative cooling towers, which often release water in an aerosol which may enter nearby ventilation intakes. Outbreaks in medical facilities and nursing homes, where patients are immuno-suppressed and immuno-weak, are the most commonly reported cases of Legionellosis. More than one case has involved outdoor fountains at public attractions. The presence of Legionella in commercial building water supplies is highly under-reported, as healthy people require heavy exposure to acquire infection.

Legionella testing typically involves collecting water samples and surface swabs from evaporative cooling basins, shower heads, faucets/taps, and other locations where warm water collects. The samples are then cultured and colony forming units (cfu) of Legionella are quantified as cfu/liter.

Legionella is a parasite of protozoans such as amoeba, and thus requires conditions suitable for both organisms. The bacterium forms a biofilm which is resistant to chemical and antimicrobial treatments, including chlorine. Remediation for Legionella outbreaks in commercial buildings vary, but often include very hot water flushes (160 °F; 70 °C), sterilisation of standing water in evaporative cooling basins, replacement of shower heads, and in some cases flushes of heavy metal salts. Preventive measures include adjusting normal hot water levels to allow for 120 °F (50 °C) at the tap, evaluating facility design layout, removing faucet aerators, and periodic testing in suspect areas.

Other bacteria

There are many bacteria of health significance found in indoor air and on indoor surfaces. The role of microbes in the indoor environment is increasingly studied using modern gene-based analysis of environmental samples. Currently efforts are under way to link microbial ecologists and indoor air scientists to forge new methods for analysis and to better interpret the results.[38]

Файл:Bacteria (26 2 27) Airborne microbes.jpg
Bacteria (26 2 27) Airborne microbes

A large fraction of the bacteria found in indoor air and dust are shed from humans. Among the most important bacteria known to occur in indoor air are Mycobacterium tuberculosis, Staphylococcus aureus, Streptococcus pneumoniae.

Asbestos fibers

Many common building materials used before 1975 contain asbestos, such as some floor tiles, ceiling tiles, shingles, fireproofing, heating systems, pipe wrap, taping muds, mastics, and other insulation materials. Normally, significant releases of asbestos fiber do not occur unless the building materials are disturbed, such as by cutting, sanding, drilling, or building remodelling. Removal of asbestos-containing materials is not always optimal because the fibers can be spread into the air during the removal process. A management program for intact asbestos-containing materials is often recommended instead.

When asbestos-containing material is damaged or disintegrates, microscopic fibers are dispersed into the air. Inhalation of asbestos fibers over long exposure times is associated with increased incidence of lung cancer, mesothelioma, and asbestosis. The risk of lung cancer from inhaling asbestos fibers is significantly greater for smokers. The symptoms of disease do not usually appear until about 20 to 30 years after the first exposure to asbestos.

Although all asbestos is hazardous, products that are friable, e.g. sprayed coatings and insulation, pose a significantly higher hazard as they are more likely to release fibers to the air.[39]

Carbon dioxide

Humans are the main indoor source of carbon dioxide in most buildings. Indoor CO2 levels are an indicator of the adequacy of outdoor air ventilation relative to indoor occupant density and metabolic activity.

Indoor CO2 levels above 500 ppm can lead to higher blood pressure and heart rate, and increased peripheral blood circulation.[40] With CO2 concentrations above 1000 ppm cognitive performance might be affected, making decision making and problem solving slower but not less accurate.[41]

Indoor carbon dioxide concentrations can be used to evaluate the quality of a room or a building's ventilation.[42] To eliminate most complaints caused by CO2, the total indoor CO2 level should be reduced to a difference of no greater than 700 ppm above outdoor levels.[43] The National Institute for Occupational Safety and Health (NIOSH) considers that indoor air concentrations of carbon dioxide that exceed 1,000 ppm are a marker suggesting inadequate ventilation.[44] The UK standards for schools say that carbon dioxide levels of 800 ppm or lower indicate that the room is well-ventilated.[45]

Carbon dioxide concentrations in closed or confined rooms can increase to 1,000 ppm within 45 minutes of enclosure. For example, in a Шаблон:Convert sized office, atmospheric carbon dioxide increased from 500 ppm to over 1,000 ppm within 45 minutes of ventilation cessation and closure of windows and doors.[46]

Ozone

Ozone is produced by ultraviolet light from the Sun hitting the Earth's atmosphere (especially in the ozone layer), lightning, certain high-voltage electric devices (such as air ionizers), and as a by-product of other types of pollution.

Ozone exists in greater concentrations at altitudes commonly flown by passenger jets. Reactions between ozone and onboard substances, including skin oils and cosmetics, can produce toxic chemicals as by-products.[47] Ozone itself is also irritating to lung tissue and harmful to human health.

Outdoor air used for ventilation may have sufficient ozone to react with common indoor pollutants as well as skin oils and other common indoor air chemicals or surfaces. Particular concern is warranted when using "green" cleaning products based on citrus or terpene extracts, because these chemicals react very quickly with ozone to form toxic and irritating chemicals[48] as well as fine and ultrafine particles.[49] Ventilation with outdoor air containing elevated ozone concentrations may complicate remediation attempts.[50]

The WHO standard for ozone concentration is 60 μg/m3 for long-term exposure and 100 μg/m3 as the maximum average over an 8-hour period.[51] The EPA standard for ozone concentration is 0.07 ppm average over an 8-hour period.[52]

Particulates

Atmospheric particulate matter, also known as particulates, can be found indoors and can affect the health of occupants.

Indoor air quality standards and monitoring

Quality standards

The Clean Air Act of 1990 required the United States Environmental Protection Agency to set National Ambient Air Quality Standards (NAAQS) for six criteria air pollutants harmful to human health.[53] Ozone is one of the criteria air pollutants. Other organizations have put forth air standards such as the Occupational Safety and Health Administration (OSHA), the National Institute for Occupational Safety and Health (NIOSH), and the World Health Organization (WHO).

Real-time monitoring

Since indoor air pollutants can adversely affect human health, it is important to have real-time indoor air quality assessment/monitoring system that can help not only in the improvement of indoor air quality but also help in detection of leaks, spills in a work environment and boost energy efficiency of buildings by providing real-time feedback to the heating, ventilation, and air conditioning (HVAC) system(s).[54] Additionally, there have been enough studies that highlight the correlation between poor indoor air quality and loss of performance and productivity of workers in an office setting.[55]  

Combining the Internet of Things (IoT) technology with real-time IAQ monitoring systems has  tremendously gained momentum and popularity as interventions can be done based on the real-time sensor data and thus help in the IAQ improvement.[56]   

Health effects

Cognitive performance

Indoor concentrations of carbon dioxide can impair cognitive performance, especially when doing complex tasks.[57]

Improvement measures

Шаблон:Expand section

Шаблон:See also Шаблон:FurtherA report assisted by the Institute for Occupational Safety and Health of the German Social Accident Insurance can support in the systematic investigation of individual health problems arising at indoor workplaces, and in the identification of practical solutions.[58]

Effect of indoor plants

Файл:Spider Plant Blades.JPG
Spider plants (Chlorophytum comosum) absorb some airborne contaminants.

Houseplants together with the medium in which they are grown can reduce components of indoor air pollution, particularly volatile organic compounds (VOC) such as benzene, toluene, and xylene. Plants remove CO2 and release oxygen and water, although the quantitative impact for house plants is small. The interest in using potted plants for removing VOCs was sparked by a 1989 NASA study conducted in sealed chambers designed to replicate the environment on space stations. However, these results suffered from poor replication[59] and are not applicable to typical buildings, where outdoor-to-indoor air exchange already removes VOCs at a rate that could only be matched by the placement of 10–1000 plants/m2 of a building's floor space.[60]

Plants also appear to reduce airborne microbes and molds, and to increase humidity.[61] However, the increased humidity can itself lead to increased levels of mold and even VOCs.[62]

When carbon dioxide concentrations are elevated indoors relative to outdoor concentrations, it is only an indicator that ventilation is inadequate to remove metabolic products associated with human occupancy. Plants require carbon dioxide to grow and release oxygen when they consume carbon dioxide.

Since extremely high humidity is associated with increased mold growth, allergic responses, and respiratory responses, the presence of additional moisture from houseplants may not be desirable in all indoor settings if watering is done inappropriately.[63]

HVAC design

Шаблон:Main Шаблон:More citations needed section

Environmentally sustainable design concepts include aspects of commercial and residential heating, ventilation and air-conditioning (HVAC) technologies. Among several considerations, one of the topics attended to is the issue of indoor air quality throughout the design and construction stages of a building's life.

One technique to reduce energy consumption while maintaining adequate air quality, is demand controlled ventilation. Instead of setting throughput at a fixed air replacement rate, carbon dioxide sensors are used to control the rate dynamically, based on the emissions of actual building occupants.

One way of quantitatively ensuring the health of indoor air is by the frequency of effective turnover of interior air by replacement with outside air. In the UK, for example, classrooms are required to have 2.5 outdoor air changes per hour. In halls, gym, dining, and physiotherapy spaces, the ventilation should be sufficient to limit carbon dioxide to 1,500 ppm. In the US, ventilation in classrooms is based on the amount of outdoor air per occupant plus the amount of outdoor air per unit of floor area, not air changes per hour. Since carbon dioxide indoors comes from occupants and outdoor air, the adequacy of ventilation per occupant is indicated by the concentration indoors minus the concentration outdoors. The value of 615 ppm above the outdoor concentration indicates approximately 15 cubic feet per minute of outdoor air per adult occupant doing sedentary office work where outdoor air contains 385 ppm, the current global average atmospheric CO2 concentration. In classrooms, the requirements in the ASHRAE standard 62.1, Ventilation for Acceptable Indoor Air Quality, would typically result in about 3 air changes per hour, depending on the occupant density. As the occupants are not the only source of pollutants, outdoor air ventilation may need to be higher when unusual or strong sources of pollution exist indoors.

When outdoor air is polluted, then bringing in more outdoor air can actually worsen the overall quality of the indoor air and exacerbate some occupant symptoms related to outdoor air pollution. Generally, outdoor country air is better than indoor city air.

Файл:Fans by Dyson 1 2018-06-02.jpg
Air-purifiers with air flow generated by bladeless fan. Some models can be used as humidifiers or heaters. Features like oscillation and adjustment of air flow angle are also available.

The use of air filters can trap some of the air pollutants. Portable room air cleaners with HEPA filters can be used if ventilation poor or outside air has high level of PM 2.5.[58] Air filters are used to reduce the amount of dust that reaches the wet coils. Dust can serve as food to grow molds on the wet coils and ducts and can reduce the efficiency of the coils.

Moisture management and humidity control requires operating HVAC systems as designed. Moisture management and humidity control may conflict with efforts to conserve energy. For example, moisture management and humidity control requires systems to be set to supply make-up air at lower temperatures (design levels), instead of the higher temperatures sometimes used to conserve energy in cooling-dominated climate conditions. However, for most of the US and many parts of Europe and Japan, during the majority of hours of the year, outdoor air temperatures are cool enough that the air does not need further cooling to provide thermal comfort indoors. However, high humidity outdoors creates the need for careful attention to humidity levels indoors. High humidity give rise to mold growth and moisture indoors is associated with a higher prevalence of occupant respiratory problems.

The "dew point temperature" is an absolute measure of the moisture in air. Some facilities are being designed with the design dew points in the lower 50s °F, and some in the upper and lower 40s °F. Some facilities are being designed using desiccant wheels with gas-fired heaters to dry out the wheel enough to get the required dew points. On those systems, after the moisture is removed from the make-up air, a cooling coil is used to lower the temperature to the desired level.

Commercial buildings, and sometimes residential, are often kept under slightly positive air pressure relative to the outdoors to reduce infiltration. Limiting infiltration helps with moisture management and humidity control.

Dilution of indoor pollutants with outdoor air is effective to the extent that outdoor air is free of harmful pollutants. Ozone in outdoor air occurs indoors at reduced concentrations because ozone is highly reactive with many chemicals found indoors. The products of the reactions between ozone and many common indoor pollutants include organic compounds that may be more odorous, irritating, or toxic than those from which they are formed. These products of ozone chemistry include formaldehyde, higher molecular weight aldehydes, acidic aerosols, and fine and ultrafine particles, among others. The higher the outdoor ventilation rate, the higher the indoor ozone concentration and the more likely the reactions will occur, but even at low levels, the reactions will take place. This suggests that ozone should be removed from ventilation air, especially in areas where outdoor ozone levels are frequently high.

Institutional programs

Файл:ELIMINATE TRIGGERS (14305286383).jpg
EPA graphic about asthma triggers

The topic of IAQ has become popular due to the greater awareness of health problems caused by mold and triggers to asthma and allergies.

In the US, the Environmental Protection Agency (EPA) has developed an "IAQ Tools for Schools" program to help improve the indoor environmental conditions in educational institutions. The National Institute for Occupational Safety and Health conducts Health Hazard Evaluations (HHEs) in workplaces at the request of employees, authorized representative of employees, or employers, to determine whether any substance normally found in the place of employment has potentially toxic effects, including indoor air quality.[64]

A variety of scientists work in the field of indoor air quality, including chemists, physicists, mechanical engineers, biologists, bacteriologists, and computer scientists. Some of these professionals are certified by organisations such as the American Industrial Hygiene Association, the American Indoor Air Quality Council and the Indoor Environmental Air Quality Council.

On the international level, the International Society of Indoor Air Quality and Climate (ISIAQ), formed in 1991, organises two major conferences, the Indoor Air and the Healthy Buildings series.[65]

See also

References

Шаблон:Reflist

Sources

Monographs

Шаблон:Refbegin

Шаблон:Refend

Articles, radio segments, web pages

Шаблон:Refbegin

Шаблон:Refend

Further reading

External links

Шаблон:Pollution Шаблон:Natural resources Шаблон:Occupational safety and health Шаблон:HVAC Шаблон:Authority control

  1. Шаблон:Cite journal
  2. Шаблон:Cite web
  3. Шаблон:Cite journal
  4. Шаблон:Cite journal
  5. Шаблон:Cite web
  6. Шаблон:Cite journal
  7. Шаблон:Cite journal
  8. Шаблон:Cite journal
  9. U.S. Environmental Protection Agency. Office equipment: design, indoor air emissions, and pollution prevention opportunities. Air and Energy Engineering Research Laboratory, Research Triangle Park, 1995.
  10. U.S. Environmental Protection Agency. Unfinished business: a comparative assessment of environmental problems, EPA-230/2-87-025a-e (NTIS PB88-127030). Office of Policy, Planning and Evaluation, Washington, DC, 1987.
  11. 11,0 11,1 Шаблон:Cite journal
  12. Шаблон:Cite web
  13. Шаблон:Cite journal
  14. Шаблон:Cite web
  15. Шаблон:Cite journal
  16. Шаблон:Cite journal
  17. Шаблон:Cite web
  18. Шаблон:Cite book
  19. C.Michael Hogan and Sjaak Slanina. 2010, Air pollution. Encyclopedia of Earth Шаблон:Webarchive. eds. Sidney Draggan and Cutler Cleveland. National Council for Science and the Environment. Washington DC
  20. Шаблон:Cite web
  21. Шаблон:Cite book
  22. Шаблон:Cite web Шаблон:PD-notice
  23. Шаблон:Cite web
  24. 24,0 24,1 24,2 Шаблон:Cite journal
  25. Шаблон:Cite web
  26. Шаблон:Citation
  27. Шаблон:Cite journal
  28. Шаблон:Cite web
  29. Шаблон:Cite web
  30. Шаблон:Cite book
  31. Шаблон:Cite web
  32. Шаблон:Cite web
  33. Шаблон:Cite web
  34. Шаблон:Cite web
  35. Шаблон:Cite web
  36. 36,0 36,1 Шаблон:Cite web
  37. Шаблон:Cite journal
  38. Microbiology of the Indoor Environment Шаблон:Webarchive, microbe.net
  39. Шаблон:Cite journal
  40. Шаблон:Cite journal
  41. Шаблон:Cite journal
  42. Шаблон:Cite journal
  43. Шаблон:Cite web
  44. Indoor Environmental Quality: Building Ventilation Шаблон:Webarchive. National Institute for Occupational Safety and Health. Accessed 2008-10-08.
  45. Шаблон:Cite web
  46. Шаблон:Cite web
  47. Study: Bad In-Flight Air Exacerbated by Passengers Шаблон:Webarchive Talk of the Nation, National Public Radio. September 21, 2007.
  48. Шаблон:Cite web
  49. Шаблон:Cite journal
  50. Шаблон:Cite web
  51. Шаблон:Cite book
  52. Шаблон:Cite web
  53. Шаблон:Cite web
  54. Шаблон:Cite journal
  55. Шаблон:Cite journal
  56. Шаблон:Cite journal
  57. Шаблон:Cite journal
  58. 58,0 58,1 Шаблон:Cite web
  59. Шаблон:Cite journal
  60. Шаблон:Cite journal
  61. BC Wolverton, JD Wolverton. (1996). Interior plants: their influence on airborne microbes inside energy-efficient buildings Шаблон:Webarchive. Journal of the Mississippi Academy of Sciences.
  62. Шаблон:Cite web
  63. Institute of Medicine, National Academy of Sciences, 2004. "Damp Indoor Spaces and Health" Damp Indoor Spaces and Health Шаблон:Webarchive. National Academy Press
  64. Шаблон:Cite web
  65. Шаблон:Cite web